Acta Metallurgica Sinica (English Letters) >
Electrochemical corrosion behavior of 300M ultra high strength steel in chloride containing environment
Received date: 2010-02-26
Revised date: 2010-04-23
Online published: 2010-08-11
The electrochemical corrosion behavior of 300M ultra high strength steel in chloride containing environment was investigated by potentiodynamic polarization technique, electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM). The results show that uniform corrosion occurs on 300M steel during the electrochemical measurements because no anodic passivation phenomenon is observed on polarization curves within the measurement range. The tests also show that 300M steel is highly susceptible to chloride containing solution, which is characterized by corrosion current density increasing with the addition of chlorides, and corrosion potential shifting towards positive direction and corrosion resistance decreasing, positively suggesting that chloride ions speed up the corrosion rate of 300M steel. Meanwhile corrosion products on the 300M steel surface formed during the salt spray test are too loose and porous to effectively slow down the corrosion rate. Additionally, a schematic structure of uniform corrosion mechanism can explain that 300M steel has better property of stress corrosion cracking (SCC) resistance than stainless steels.
XUN Min , DONG Tiao-Fang , XIAO Kui- , LI Xiao-Gang . Electrochemical corrosion behavior of 300M ultra high strength steel in chloride containing environment[J]. Acta Metallurgica Sinica (English Letters), 2010 , 23(4) : 301 -311 . DOI: 10.11890/1006-7191-104-301
[1] M.L.A. Graca, C.Y. Hoo and O.M. Silva, Eng Fail Anal 16(1) (2009) 182.
[2] R.O. Ritchie and R.M. Horn, Metal Mater Trans A 9(3) (1978) 331.
[3] Y. Tomita and T. Okawa, Mater Sci Eng A 172(1-2) (1993) 145.
[4] C.F.G. aballero, M.J. Santofimia, C. Garcia-Mateo,S. Kaliappan, H. Shaikh, and P.V. Sivaprasad, Mater Design 30(6) (2009) 2077.
[5] H. Garbacz, M. Lewandowska, W. Pachla and K.J.Kurzydlowski, J Microsc-Oxf 223(3) (2006) 272.
[6] P.J. Antony, S. Chongdar, P. Kumar and R. Raman, Electrochim Acta 52(12) (2007) 3985.
[7] A. Igual Munoz, J. Garcia Anton, J.L Guinon and V. Perez Herranz, Corros Sci 49(8) (2007) 3200.
[8] H. Altun and S. Sen, Mater Design 25(7) (2004) 637.
[9] L.C. Chang and H.K.D.H. Bhadeshia, Mater Sci Eng A 184(1) (1994) L17.
[10] R.W. Revie and H.H. Uhlig, Corrosion and Corrosion Control, An Introduction to Corrosion Science and Engineering, 4th ed. (A John Wiley & Sons, Inc., Hoboken New Jersey, 2007)p.350.
[11] B. Diaz, L. Freire, X.R. Novoa and M.C.Perez, Electrochim Acta 54 (2009) 5190.
[12] J. Sanchez, J. Fullea, C. Andrade, J.J. Gaitero and A. Porro, Corros Sci 50 (2008) 1820.
[13] B. Jegdic, D.M. Drazic and J.P. Popic, Corros Sci 50(5) (2008) 1235.
[14] W.R. Osorio, L.C. Peixoto, L.R. Garcia and A.Garcia, Mater Corros 60(10) (2009) 804.
[15] C.O.A. Olsson and D. Landolt, Electrochim Acta 48(9) (2003) 1093.
[16] Y.F. Cheng, Bull Electrochem 21(11) (2005)503.
[17] X.L. Zhang, Z.H. Jiang, Z.P. Yao, Y. Songa and Z.D. Wub, Corros Sci 51(3) (2009) 581.
[18] M. Pisarek, P. Kedzierzawski, M. Janik-Czachor and K.J.Kurzydlowski, J Solid State Electrochem 13(2) (2009)283.
[19] T.P. Hoar and W.R. Jacob, Corros Sci 66(7) (1967) 341.
[20] P.C. Pistorius and G.T. Burstein, Corros Sci 33(12) (1992) 1885.
[21] K.V.S. Ramana, T. Anita, S. Mandal, S. Kaliappan, H.Shaikh and P.V. Sivaprasad, Mater Design 30(9) (2009)3770.
[22] S.D. Cramer, ASM Handbook: Corrosion (ASM International, United States of America, 1987) p.302.
/
| 〈 |
|
〉 |